| Cooling at 95F1 |
Maximum Capacity |
Btu/h |
11,000 |
| Rated Capacity |
Btu/h |
9,000 |
| Minimum Capacity |
Btu/h |
3,600 |
| Maximum Power Input |
W |
1,100 |
| Rated Power Input |
W |
720 |
| Moisture Removal |
Pints/h |
1.8 |
| Sensible Heat Factor |
- |
0.78 |
| Power Factor [208V / 230V] |
% |
96 / 96 |
| Heating at 47F2 |
Maximum Capacity |
Btu/h |
13,000 |
| Rated Capacity |
Btu/h |
10,900 |
| Minimum Capacity |
Btu/h |
4,000 |
| Maximum Power Input |
W |
1,400 |
| Rated Power Input |
W |
900 |
| Power Factor [208V / 230V] |
% |
99 / 99 |
| Heating at 17F3 |
Maximum Capacity |
Btu/h |
7,200 |
| Rated Capacity |
Btu/h |
6,800 |
| Maximum Power Input |
W |
1,230 |
| Rated Power Input |
W |
820 |
| Heating at 5F4 |
Maximum Capacity |
Btu/h |
7,700 |
| Maximum Power Input |
W |
1,250 |
| Heating at -5F6 |
Maximum Capacity |
Btu/h |
6,740 |
| Efficiency |
SEER2 |
|
20 |
| EER21 |
|
12.5 |
| HSPF2 [IV] |
|
10 |
| COP at 47°F2 |
|
3.55 |
| COP at 17°F at Maximum Capacity3 |
|
1.7 |
| COP at 5°F at Maximum Capacity4 |
|
1.8 |
| COP at -5°F at Maximum Capacity6 |
|
1.56 |
| ENERGY STAR® Certified |
|
Yes |
| Electrical |
Voltage, Phase, Frequency |
V AC / V AC, ø, Hz |
115 / 115, 1, 60 |
| Guaranteed Voltage Range |
V AC |
103 - 127 |
| Voltage: Indoor - Outdoor, S1-S2 |
V AC |
115 |
| Voltage: Indoor - Outdoor, S2-S3 |
V DC |
24 |
| Short-circuit Current Rating [SCCR] |
kA |
5 |
| Recommended Fuse/Breaker Size (Outdoor) |
A |
15 |
| Recommended Wire Size [Indoor - Outdoor] |
AWG |
14 |
| Indoor Unit |
MCA |
A |
1.4 |
| Fan Motor Output |
W |
30 |
| Airflow Rate at Cooling, Dry |
CFM |
146, 210, 293, 374 |
| Airflow Rate at Cooling, Wet |
CFM |
131, 189, 263, 337 |
| Airflow Rate at Heating, Dry |
CFM |
146, 219, 313, 384 |
| Sound Pressure Level [Cooling] |
dB (A) |
22, 30, 37, 43 |
| Sound Pressure Level [Heating] |
dB (A) |
22, 30, 37, 43 |
| Drain Pipe Size O.D. |
inch [mm] |
5/8 [15.88] |
| External Finish Color |
|
Munsell 0.7PB 9.2/0.4 |
| Unit Dimensions (W x D x H) |
inch x inch x inch [mm x mm x mm] |
33 x 9-1/4 x 11-1/32 [838 x 235 x 280] |
| Package Dimensions (W x D x H) |
inch x inch x inch [mm x mm x mm] |
36 x 13-1/4 x 11-1/2 [920 x 340 x 300] |
| Unit Weight |
lbs [kg] |
20 [9] |
| Package Weight |
lbs [kg] |
24 [10.50] |
| Fan Motor Type |
|
DC Motor |
| IDU Operating Temp. Range |
Cooling Intake Air Temp [Maximum / Minimum] |
°FDB, °FWB / °FDB,
°FWB |
90, 73 / 67, 57 |
| Heating Intake Air Temp [Maximum / Minimum] |
°FDB |
80 / 70 |
NOTES
1Cooling at 95°F (Indoor: 80°F DB, 67°F WB // Outdoor: 95°F DB, 75°F WB) 2Heating at 47°F (Indoor: 70°F DB, 60°F WB // Outdoor: 47°F DB, 43°F WB) 3Heating at 17°F (Indoor: 70°F DB, 60°F WB // Outdoor: 17°F DB, 15°F WB) 4Heating at 5°F (Indoor: 70°F DB, 60°F WB // Outdoor: 5°F DB, 4°F WB) 6Heating at -5°F (Indoor: 70°F DB, 60°F WB // Outdoor: -5°F DB, -6°F WB)
* Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
• Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
** Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
• System cuts out in heating mode and automatically restarts at these temperatures. |
| Outdoor Unit |
MCA |
A |
15 |
| MOCP |
A |
26 |
| Fan Motor Full Load Amperage |
A |
0.5 |
| Fan Motor Output |
W |
55 |
| Airflow Rate Cooling |
CFM |
1,305 |
| Airflow Rate Heating |
CFM |
1,196 |
| Defrost Method |
|
Reverse Cycle |
| Coating on Heat Exchanger (Bluefin, Sea Coast) |
|
Yes, Yes |
| Sound Pressure Level, Cooling1 |
dB (A) |
46 |
| Sound Pressure Level, Heating2 |
dB (A) |
50 |
| Compressor Type |
|
Single Rotary |
| Compressor Model |
|
KRB073FATMC |
| Compressor Oil [Type // Charge] |
Type // oz |
RM68EH // 9.1 |
| External Finish Color |
|
Munsell 3Y 7.8/1.1 |
| Base Pan Heater |
|
Optional |
| Unit Dimensions (W x D x H) |
inch x inch x inch [mm x mm x mm] |
31/-1/2 x 11-1/4 x 21/5/8 [800 x 285 x 550] |
| Package Dimensions (W x D x H) |
inch x inch x inch [mm x mm x mm] |
36 x 13-1/4 x 11-1/2 [920 x 340 x 300] |
| Unit Weight |
lbs [kg] |
20 [9] |
| Package Weight |
lbs [kg] |
24 [10.50] |
| ODU Operating Temp. Range |
Cooling Intake Air Temp [Maximum / Minimum*] |
°FDB |
115 / 14 |
| Cooling Thermal Lock-out / Re-start Temperatures** |
°FDB |
-1 / 3 |
| Heating Intake Air Temp [Maximum / Minimum] |
°FDB, °FWB / °FDB,
°FWB |
75, 65 / -5, -6 |
| Heating Thermal Lock-out / Re-start Temperatures** |
°FDB |
-14 / -4 |
| Refrigerant |
Type |
|
R454B |
| Pre-Charged Refrigerant Amount |
lbs, oz |
1, 6 |
| Maximum Pre-Charged Piping Length |
ft [m] |
25 [7.50] |
| Additional Refrigerant Charge Per Additional Piping Length |
oz/ft |
0.22 |
| Piping |
Gas Pipe Size O.D. [Flared] |
inch [mm] |
3/8 [9.52] |
| Liquid Pipe Size O.D. [Flared] |
inch [mm] |
1/4 [6.35] |
| Maximum Piping Length |
ft [m] |
65 [20] |
| Maximum Height Difference |
ft [m] |
40 [12] |
| Maximum Number of Bends |
|
10 |
NOTES
1Cooling at 95°F (Indoor: 80°F DB, 67°F WB // Outdoor: 95°F DB, 75°F WB) 2Heating at 47°F (Indoor: 70°F DB, 60°F WB // Outdoor: 47°F DB, 43°F WB) 3Heating at 17°F (Indoor: 70°F DB, 60°F WB // Outdoor: 17°F DB, 15°F WB) 4Heating at 5°F (Indoor: 70°F DB, 60°F WB // Outdoor: 5°F DB, 4°F WB) 6Heating at -5°F (Indoor: 70°F DB, 60°F WB // Outdoor: -5°F DB, -6°F WB)
* Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
• Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
** Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
• System cuts out in heating mode and automatically restarts at these temperatures. |
| Condensate |
Blue Diamond Advanced Mini Condensate Pump w Reservoir Sensor 208230V recommended |
X87-721 |
| Blue Diamond MaxiBlue Advanced Mini Condensate Pump w Reservoir Sensor 110V up to 48000 BTUH recommended |
X87-711 |
| Blue Diamond MegaBlue Advanced Condensate Pump w Reservoir Sensor |
X87-835 |
| Blue Diamond MicroBlue Mini Condensate Pump 110208230V up to 18000 BTUH |
X86-003 |
| Blue Diamond Sensor Extension Cable 15 Ft |
C13-103 |
| Drain Pan Level SensorControl |
SS610E |
| Refco Condensate Pump 100-240 VAC up to 120000 BTUH |
COMBI |
| Refco Condensate Pump 100-240 VAC |
GOBI-II |
| REFCO PUMP 100-240 VAC 506O HZ |
X86-011 |
| Sauermann Condensate Pump |
SI30-230 |
| Control Interface |
Airzone Wired Blueface Controller Black |
AZZBSBLUEZEROCN |
| Airzone Wired Blueface Controller White |
AZZBSBLUEZEROCB |
| Airzone Wireless Lite Controller Black |
AZZBSLITERN |
| Airzone Wireless Lite Controller White |
AZZBSLITERB |
| Airzone Wireless Think Controller Black |
AZZBSTHINKRN |
| Airzone Wireless Think Controller White |
AZZBSTHINKRB |
| IT Extender for kumo station |
PAC-WHS01IE-E |
| kumo station for the Comfort app |
PAC-WHS01HC-E |
| M-Net I/O Control Interface for M-Series 2 |
MAC-334IF-E |
| Procon BACnet and Modbus Interface |
PAC-UKPRC001-CN-1 |
| Thermostat Interface for 3rd Party Thermostats |
PAC-US445CN-1 |
| Wireless Interface Adapter for the Comfort app |
PAC-USWHS002-WF-2 |
| Drain Hose |
Flexible Mini-Split Drain Hose |
DRX-16 |
| Wireless Remote Controller |
Lockdown Bracket for Wireless Handheld Remote Controllers |
RCMKP1CB |
| RedLINK Wireless Remote Controller |
MHK2 |
| Power Supplies and Auxiliary Components |
Backup Heat Relay Kit Adapter for CN24 or CN152 Connector |
CN24RELAY-KIT-CM3 |
| Lineset |
15 x 1/4 x 15 3/8 Lineset Twin-Tube Insulation |
MLS143812T-15 |
| 30 x 1/4 x 30 3/8 Lineset Twin-Tube Insulation |
MLS143812T-30 |
| 50 x 1/4 x 50 3/8 Lineset Twin-Tube Insulation |
MLS143812T-50 |
| 65 x 1/4 x 65 3/8 Lineset Twin-Tube Insulation |
MLS143812T-65 |
| Remote Sensor |
Remote Temperature Sensor for MFZ MLZ and MSZ models |
M21EAA307 |
| Wireless temperature and humidity sensor for the Comfort app |
PAC-USWHS003-TH-1 |
| Wired Remote Controller |
Deluxe Wired MA Remote Controller 1 |
PAR-42MAAUB |
| Simple Direct Wired Remote Controller |
PAC-SDW01RC-1 |
| Simple MA Remote Controller1 |
PAC-YT53CRAU-J |
| Touch MA Wired Remote Controller1 |
PAR-CT01MAU-SB |
| Filter |
Electro Static Anti-allergy Enzyme Filter |
MAC-2320FT-E |
| Microparticle Filter |
MAC-EMF515FT-E |
| Disconnect Switch |
30A600VUL fits 2 X 4 utility box - Black |
TAZ-MS303 |
| 30A600VUL fits 2 X 4 utility box - White |
TAZ-MS303W |
NOTES
1Requires MAC-334IF-E Interface to connect MA controller 1Requires MAC-334IF-E Interface to connect MA controller 1Requires MAC-334IF-E Interface to connect MA controller 2Allows IDU Connection to MA Controller:
Deluxe MA Remote Controller
Simple MA Controller Touch MA Controller |
| Mini-Split Wire |
14 Gauge 4 wire Armored MiniSplit Cable250 ft roll |
SW144-250 |
| 14 Gauge 4 wire Armored MiniSplit Cable50 ft roll |
SW144-50 |
| 14 Gauge 4 wire MiniSplit Cable250 ft roll |
S144-250 |
| 14 Gauge 4 wire MiniSplit Cable50 ft roll |
S144-50 |
| Snow/Rain Diverter |
SnowRain Diverter |
SRD-1 |
| Stand |
18 Single Fan Stand |
QSMS1801M |
| 24 Single Fan Stand |
QSMS2401M |
| Condenser Wall Bracket - Stainless Steel Finish |
QSWBSS |
| Condenser Wall Bracket |
QSWB2000M-1 |
| Outdoor Unit 3-14 inch Mounting Base Pair - Plastic |
DSD-400P |
| Outdoor Unit Stand 12 High |
QSMS1201M |
| Drain Socket |
Drain Socket |
MAC-871DS |
| Air Outlet Guide |
Air Outlet Guide |
MAC-881SG-E |
| Mounting Pad |
Condensing Unit Mounting Pad 16 x 36 x 3 |
ULTRILITE1 |
| Control/Service Tool |
M- & P-Series Maintenance Tool Cable Set |
M21EC0397 |
| Maintenance Tool Interface |
PAC-USCMS-MN-1 |
| Hail Guards |
Hail Guard |
HG-B4 |
| NOTES |